TP-Link Kasa EP10 Relay and LED Control
Read and switch a compatible TP-Link Kasa EP10 through its legacy local TCP protocol with Muse Home Link. Verify relay and inverted LED state; EP10 does not provide energy metering.
TP-Link Kasa EP10: Relay and LED Control
Use this skill when fresh discovery and a scoped device read confirm a compatible Kasa EP10 and the user requests plug status or switching.
Humans to Know editorial context
Use the pinned Muse Gadget SDK repository for runtime setup. Existing LAN-device clients run on its Linux Home Link through system.run; the Muse app, SDK token and VM connection remain required.
Community-sourced instructions, not an official integration. Read repository-context.md before using this standalone package; it identifies the exact upstream repository, runtime dependencies and evidence to hand back. The original workflow and device limits below are retained.
Modified-file notice: Humans to Know added the editorial context and standalone reference links to this upstream skill.
Identify the Device
- Confirm exact model, hardware and firmware from legacy
system.get_sysinfo, not a vendor prefix or open port. - Use its discovered local TCP endpoint; the legacy service commonly uses 9999. Do not run client UDP discovery from the agent.
Prerequisites
Read the Humans to Know editorial repository context for the pinned SDK, Linux execution boundary and task-specific verification. This supplement resolves the missing public home_link.md reference.
- Know the connected load and confirm that switching it is intended.
- The legacy interface needs no account credentials. If current firmware identifies a different protocol, do not force legacy XOR or silently switch to another family's skill.
Workflow
- Use python-kasa's explicitly configured legacy IOT plug client through the shared network access; supply the known endpoint without broadcast discovery.
- For an agent-authored transport, legacy TCP frames use a four-byte big-endian payload length and TP-Link's documented XOR-autokey JSON encoding; prefer the maintained implementation over inventing encryption.
- Read
{"system":{"get_sysinfo":{}}}and retainrelay_stateandled_off. - Set the relay using
system.set_relay_statewithstate1 or 0, or the client'sturn_on/turn_off. Setsystem.set_led_offonly when an LED change is requested;off:1disables the LED. - Refresh the device state after each action. Check device error codes, not merely receipt of a TCP frame.
Verify the Result
- Confirm the desired relay state; LED state is separate and inverted by
led_off. - A relay acknowledgement does not prove the connected appliance performed its own task.
- If a response is uncertain, read state before retrying; do not retry with a toggle.
Limits
- EP10 has no energy meter. Do not promise watts, energy history or EP25 authentication/features.
- No reset, network changes, credential updates, schedules or firmware actions.